AC-DC Power Supplies: CCL400 Series
Published on : Tuesday 30-11--0001
- 400 W Convection-cooled
- Conduction Cooling For Higher Ambient Operation
- 94% Efficiency
- 85 VAC to 264 VAC Input
- 5V Standby
- <1W Standby Power
- IT & Medical Safety Approvals
- Power Fail & Inhibit Signals
- 3 Year Warranty
Specifications:
Dimensions:
- CCL: 7.12 x 3.95 x 1.57 in (180.9 x 100.3 x 39.9 mm)
Input Voltage:
- 85-264 VAC (see datasheet)
No Load Input Power:
- 1 W max
Harmonic Currents:
- EN61000-3-2, class A
Efficiency:
- 93-94%
Operating Temp:
- -40 °C to +70 °C. Refer to derating curves
Isolation:
- 4000 VAC Input to Output, 2 x MOPP
- 1500 VAC Input to Ground 1 x MOPP
- 500 VAC Output to Ground
Worldwide Safety Approvals:
- IEC60950-1 Ed 2, IEC60601-1 Ed 3.1 Including Risk Management
European Safety Approvals:
- EN60950-1, EN60601-1, CE Mark
US Safety Approvals:
- UL60950-1, CSA C22.2 No. 60601-1:08, ANSI/AAMI ES60601-1
EMC:
- EN55022, Level B conducted and Level A radiated (Level B see datasheet)
XP Power Singapore Holding Pte Ltd,Bangalore,Tel:+91 98867 68870,Email:[email protected]