iTHERM TrustSens TM371
Published on : Tuesday 30-11--0001
Compact thermometer for hygienic and aseptic applications
The iTHERM TrustSens hygienic thermometer is for users in the Life Sciences and Food and Beverages industries who want seamless compliance to FDA regulations and/or GMP rules. iTHERM TrustSens eliminates the risk of undetected non–conformities and is differentiated by automated inline self-calibrations before each batch during the SIP resulting in maximized product safety and process efficiency.
Benefits
- Risk and cost reduction thanks to self-calibration and Heartbeat Technology
- No production downtime due to an automated and fully traceable inline self-calibration
- Automatized documentation, memory for 350 calibration points
- Printable calibration certificate - audit proof
- Elimination of non-conformities or undetected failures
- International certifications and approvals:
- – EHEDG, ASME BPE, FDA, 3-A, 1935/2004, 2023/2006, 10/2011, CE CRN, CSA General Purpose
- Highest accuracy of measuring point through sensor-transmitter-matching
Field of application
- Specially designed for use in hygienic and aseptic applications in the food & beverages and life sciences industries
- Measuring range: –40 to 160 °C (–40 to 320 °F)
- Pressure range up to 50 bar (725 psi)
- Protection class IP67/68 or IP69K
- Communication: Analog output 4 to 20 mA, HART ® protocol
Features and specifications
Thermometer
Measuring Principle |
Resistance Temperature Detector |
|
Characteristic / Application |
self-calibrating |
|
Thermowell / protection tube |
without |
|
Insert / probe |
pipe version, isolated wires, not flexible |
|
Outer diameter protection tube |
6,0 mm (0,24'') |
|
Max. immersion length on request |
up to 900,00 mm (35,4'') |
|
Material protection tube/ thermowell |
1.4435 Delta-Ferrit < 1% |
|
Process connection |
compression fitting |
|
Tip shape |
straight |
|
Surface roughness Ra |
0,76 μm (29,92 μin) |
|
Operating temperature range |
PT 100: |
|
Max. process pressure (static) |
at 20 °C: 40 bar (580 psi) |
|
Response time |
t50 = 2,5 s |
|
Integration head transmitter |
no (4…20mA Signal, HART) |
It is used in food & beverages and life sciences industries.