Spool Piece Ultrasonic Flowmeter
Published on : Tuesday 30-11--0001
Three pairs of sensors for accuracy of ±0.2% of rate
High accuracy
±0.2% of rate
Using the new algorithm for calculating the flow velocity, it can measure any type of fluid with high accuracy.
Low maintenance
With no moving parts, FST has long-term stability while requiring only minimal maintenance work.
Bubble resistant
By using the advanced anti-bubble measurement technology, the interference from air bubbles is greatly eliminated.
Wide temperature range from -40°C to +150°C
Non conductive fluid including oil, mixed liquid, purified water can be measured.
Easy-to-operate
with backlit LCD and front panel operation
General Specifications
Principle |
Transit time difference method with the advanced ABM (anti-bubble measurement) system |
||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe diameter (mm) |
50 mm, 80 mm, 100 mm |
||||||||||||
Flow velocity range |
Minimum 0 to 0.3 m/s or -0.3 to 0 m/s |
||||||||||||
Flow range |
|
||||||||||||
Power supply |
100–240 V AC (+10% -15%), 50/60 Hz or 20–30 V DC |
||||||||||||
Power consumption |
Approx. 20 VA (AC power), Approx. 6W (DC power) |
||||||||||||
Arrestor |
provided as standard, on power supply port and analog output port |
||||||||||||
Enclosure |
IP66 |
||||||||||||
Operating environment |
-40°C to +60°C, RH 90% or less |
Fluid Conditions
Fluid |
Liquid (uniform liquid through which ultrasonic wave can propagate) |
---|---|
Bubble content |
≤ 12 vol% |
Turbidity |
≤ 10,000 mg/L |
Fluid condition |
fully-developed turbulent or laminar flow in a fully-filled pipe |
Fluid temperature |
-40°C to +150? |
Pressure |
Up to flange rating |
Kinematic viscosity |
≤ 100 mm2/s |
Detector
Wetted parts material |
Flow cell: stainless steel 316L |
---|---|
Housing |
SCS13 |
Process connections |
Flange (horizontal or vertical mounting) |
Flange rating |
JIS10K/JIS20K |
Performance
Accuracy |
±0.2% of rate (flow velocity: 1 m/s to 10 m/s) |
---|---|
Response time |
1.2 s (standard) |
Flow Transmitter
Analog output signal |
4–20 mA DC (insulated), 1 point, allowable load resistance: 600Ω or less |
---|---|
Contact output |
Forward total, reverse total, alarm, acting range, flow switch, or total switch |
Communication (option) |
RS-485 (MODBUS), isolated, arrestor incorporated |
Display |
16-digit 2-line backlit LCD |
Language |
Japanese (katakana), English, French, German, Spanish (switchable) |
Flow velocity/flow rate indication |
8 digits numerals (decimal point is counted as 1 digit) |
Total value indication |
Integrated value of forward flow or reverse flow (reverse flow is indicated with minus symbol) |
Housing material |
Aluminum alloy |
Coating/finish color |
Urethane resin/silver |
Wiring port |
G1/2 internal thread |
Terminals |
Rod terminal |
Functions
Zero point adjustment |
By setting zero or clearing zero |
---|---|
Damping |
For analog output or velocity/flow rate indication, 0 to 100 seconds |
Low flow cut-off |
0 to 5 m/s in terms of flow velocity |
Alarm |
For hardware error or process error |
Output burnout |
Hold, overscale, underscale, or zero |
Output limit |
High/low limit for analog output is available in the range from 0.8 mA to 23.2 mA |
Bi-directional range |
Forward and reverse ranges configurable independently. |
Auto-switchable two ranges |
User configurable |
Flow switch |
Contact output available at user-defined H/L limit |
Total switch |
High limit for total flow |
Total preset |
Total flow returns to the user-defined preset value every time a user resets the total. |
Data backup at power outage |
On nonvolatile memory |
It is used in Water Treatement, Steel, Petro-Chemical, Pulp And Paper Industry.
Fuji Electric India Pvt. Ltd
Tel: 088790 90765
Email: [email protected]