Photolytic True NO2/NO/NOx Analyzer
Published on : Tuesday 30-11--0001
Description
The Model T200P provides measurements of NO and NO2 using our Model T200 NOx analyzer combined with a patented high efficiency photolytic converter. Even low temperature molybdenum converters transform other nitrogen-containing compounds such as HNO3, PAN, etc. to a considerable extent. Simultaneous measurements of NO2 performed with molybdenum and photolytic converters have shown significantly different results in the presence of such compounds.
In the photolytic process the sample gas passes through a cell where it is exposed to light at a specific wavelength from an LED array. This causes the NO2 to be selectively converted to NO with negligible interference from other gases. Advances in the photolytic converter technology now yields NO2 conversion efficiency that is similar to molybdenum under typical ambient NO2 concentrations, but without the same interferences.
All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/0, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.
The Model T200P comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software. ?
Features
- Ranges: 0-50 ppb to 0-4,000 ppb, user selectable
- High efficiency photolytic converter with specific conversion of NO2
- Ethernet, RS-232, and (optional) USB com ports
- Front panel USB connections for peripheral devices and firmware upgrades
- 8 analog inputs (optional)
- 0.40 ppb lower detectable limit
- Catalytic ozone scrubber
- Comprehensive internal data logging with programmable averaging periods
- Ability to log virtually any operating parameter
- Two-year warranty
Specifications
Ranges |
Min: 0 - 50 ppb full scale for NO and NO2 |
Measurement Units |
ppb, ppm, μg/m3, mg/m3 (selectable) |
Zero Noise |
< 0.2 ppb (RMS) |
Span Noise |
< 0.5% of reading (RMS) above 50 ppb |
Lower Detectable Limit |
0.4 ppb |
Zero Drift |
< 0.5 ppb/24 hours |
Span Drift |
< 0.5% of full scale/24 hours |
Lag Time |
20 seconds |
Rise/Fall Time |
< 60 seconds to 95% |
Linearity |
1% of full scale |
Precision |
0.5% of reading above 50 ppb |
Sample Flow Rate |
500 cc/min ±10% |
Power Requirements |
100V-120V, 220V-240V, 50/60 Hz |
Analog Output Ranges |
10V, 5V, 1V, 0.1V (selectable) |
Recorder Offset |
±10% |
Included I/O |
1 x Ethernet: 10/100Base-T |
Optional I/O |
1 x USB com port |
Operating Temperature Range |
5 - 40ºC |
Dimensions (HxWxD) |
7” x 17” x 23.5” (178 x 432 x 597 mm) |
Weight |
Analyzer: 40 lbs (18 kg) |
?Certifications: |
?US EPA: EQNA-1016-241 |
It is used in Chemical, Oil And Gas Industry.
Teledyne Instruments(USA)
Tel: +1-858-657-9800
Email: [email protected]