YTA610 Temperature Transmitter
Published on : Tuesday 30-11--0001
The YTA610 provides high accuracy, stability, and reliability. The housing structure adopts reliable dual-compartment structure. The sensor input can be choice of single or dual inputs. This input can accept the RTD, thermocouple, ohm, or DC millivolt. It converts the sensor input to a 4 to 20 mA DC analog signal or Fieldbus digital signal. HART® 7 Protocol or FOUNDATION™ Fieldbus ITK 6 version are available. The dual input can accept two sensors calculation of the differential or average value and the sensor backup function. Sensor backup functions for automatically switches-over from the primary to the backup upon sensor failure.
By adoption of local parameter switch on the Indicator, it becomes easy to do the on-site setting work.
YTA610 features include:
- Dual-compartment field-mount housing
- Choice of HART® 7, or FOUNDATION™ Fieldbus ITK 6 Protocol
- Local Parameter Setting function (Indicator model)
- Basic diagnosis
Total Insight
From ‘Sensing’ to ‘Sensemaking’
Combining reliable technology with superior field knowledge, Yokogawa has insights into the lifecycle of the device that provides added value to the user.
YTA Total Insight offers valuable information throughout the devices’ lifecycle.
Sensing Selection : - Engineering and Procurement -
Simple lineup and a wide range of international approvals help the customer select the right product.
Easy Installation : - Configuration and Commissioning -
Various ways of configuring devices contribute to reduced installation and configuration time.
Rich Information : - Operation and Observation -
Valuable diagnostic information leads to improved process efficiency.
Expert Solution?- Maintenance and Service
Providing timely maintenance information contributes to reduced maintenance cost.
Accuracy
The YTA610 enables advanced linearization of 21 types of industrial temperature sensors and input signals. The A/D accuracy of the representative Pt100 sensor is 0.14?. Analog D/A accuracy of the output is 0.03%.
Communications
The YTA610 has 4 to 20 mA analogue output signal with HART® 7 digital protocol or full digital FOUNDATION™ Fieldbus protocol.
Dual sensor input
The YTA610 in capable of dual sensor input. With the processing capability of the transmitter, this dual input can be used to provide Failed Sensor Backup, Temperature Averaging, or Differential Temperature measurement.
Sensor Matching
The Yokogawa YTA610 uses the IEC60751 standard to define the relationship between resistance and temperature for RTD sensors. This relationship is referred to as a Standard Curve. Sensor manufacturers use this same standard, but, because of construction process, each sensor has a unique temperature / resistance relationship. This is referred to as the Real RTD Curve. (The Real RTD Curve falls within the tolerance band of IEC60751 standard) In the 1920's, Hugh Longbourne Callendar and M.S. Van Dusen developed a set of coefficients that would modify the Standard Curve to match the Real RTD Curve; thus, removing the error generated by the difference between the two curves. Yokogawa's YTA610 with the CM1 option can accept these coefficients to adjust the Standard Curve to match the Real RTD Curve of the sensor; eliminating this error improves the accuracy of the YTA610 / Sensor system.
It is used in Oil And Gas Industry.
Yokogawa India Ltd.
Phone: 022 2839 3719
Email: [email protected].