OPTIWAVE 1010
Published on : Tuesday 30-11--0001
Product highlights
- Welded to a bypass chamber with optional IP 68 indicator
- No minimum dielectric constant when equipped with a float
- Dual process seal system with Metaglas® or Metapeek
- Aluminium or stainless steel housing
- Pre-configured in the factory and ready to use (plug & play)
- Accuracy: ± 5 mm / 0.2" uncertainty
- 2-wire, 4…20 mA/HART®
- PACTwareTM, HART® DDs and DTMs provided free of charge with full functionality
Typical applications
Clean liquids in bypass chambers or magnetic level indicators, e.g. solvents, alcohols, bases, condensates, liquefied gases, hydrocarbons, hydraulic or motor oil, engine coolants, washing fluids, cooling or drinking water
Technical data
Product type |
Level transmitter |
Measurement principles |
Float in bypass, Radar |
Level measurement type |
Continuous measurement |
Measured media |
Liquids |
Contact to measured medium |
No |
Interface measurement |
No |
Measuring range (liquids) |
0.3…8 m/ |
Process pressure (relative) |
-1…40 barg/ |
Process temperature |
-40…150°C/ |
Wetted parts |
Polyetheretherketone (PEEK), Austenitic stainless steel (1.4404/316L) |
Process seals |
EPDM, Kalrez® 6375, FKM/FPM |
Accuracy (liquids) |
±5 mm/ |
It is used in chemical, power, water and wastewater industry
KROHNE MARSHALL Pvt Ltd.
Phone: 020 3985 8555
Email: [email protected]